Bateria Slany Ultra Prima

Fotografia baterie Bateria Slany Ultra PrimaFotografia baterie Bateria Slany Ultra Prima    

Measurement Chart of discharging current 220 mA

 

Other measured values:
AmpHrs
Current
Watts
WattHrs
Discharging current:
Effective capacity of the battery by voltage 0,8V is 0.536 Ah

Maximum capacity of the battery by voltage 0,1V is 0.829 Ah
Table of measured values of the discharging current 220 mA
Time 00:0000:2000:4001:0001:3001:5002:1002:3003:0003:2003:4003:5804:28
Volts 1.3150.9761.1371.1091.0510.9770.8850.8170.6870.5250.2660.1660.102
Amps 0.230.20.210.210.210.20.190.190.180.170.150.120.1
Watts 0.3020.1950.2390.2330.2210.1950.1680.1550.1240.0890.040.020.01
AmpHrs 0.0040.0750.150.220.3270.3950.4620.5260.6180.6790.7340.7770.829
WattHrs 0.0050.0880.1730.2520.3680.4370.4980.5550.6190.6540.6770.6860.692
Compare with: