DURACELL 800

Fotografia baterie DURACELL 800Fotografia baterie DURACELL 800    

Measurement Chart of discharging current 130 mA

 

Other measured values:
AmpHrs
Current
Watts
WattHrs
Discharging current:
Effective capacity of the battery by voltage 0,8V is 0.767 Ah

Maximum capacity of the battery by voltage 0,1V is 0.785 Ah
Table of measured values of the discharging current 130 mA
Time 00:0000:4001:2002:0002:4003:2004:0004:4005:2006:0006:5007:3008:11
Volts 1.3731.261.2221.2041.1991.1941.1891.1841.1751.151.0630.2220.101
Amps 0.120.110.110.110.110.110.110.110.110.10.10.012.429
Watts 0.1650.1390.1340.1320.1320.1310.1310.130.1290.1150.1060.0022.453
AmpHrs 0.0020.0790.1530.2260.2990.3730.4460.5190.5920.6620.7450.780.785
WattHrs 0.0030.1040.1950.2830.3710.4590.5460.6330.7190.8010.8930.9210.922